An image of Fitting, 1-Port Spillout to 1.5
FIDT2X2BL

Used to route cable into one piece of 1.5" (38mm) diameter split corrugated tubing. Used with a Spill-Over Junction with a 2x2 exit, 2x2 Fiber-Duct™ Fittings, and the 2x2 FiberRunner® Hinged Channel, Black.

An image of Fitting, 1-Port Spillout to 1.5
FIDT2X2OR

Used to route cable into one piece of 1.5" (38mm) diameter split corrugated tubing. Used with a Spill-Over Junction with a 2x2 exit, 2x2 Fiber-Duct™ Fittings, and the 2x2 FiberRunner® Hinged Channel, Orange.

An image of Fitting, 1-Port Spillout to 1.5
FIDT2X2YL

Used to route cable into one piece of 1.5" (38mm) diameter split corrugated tubing. Used with a spill-over junction with a 2x2 exit, 2x2 Fiber-Duct™ Fittings, and the 2x2 FiberRunner® Hinged Channel, Yellow.

An image of Kit, 2
FRHD2KTBL

Provides secure, accessible route for cables spilling out from a vertical tee or spill-over junction to rack mounted equipment. Kit includes 6' length of 2x2 FiberRunner® Hinged Channel H2X2BL6, 6' length of 2x2 snap-on hinged cover HC2BL6, four adjustable "Z" brackets FZBA1.5X4, one FiberRunner® 2x2 End Cap FHDEC2X2BL, six hinged duct 2" wire retainers WR2H-C and all required mounting hardware. Attaches to 2x2 vertical tee exit or spill-over junction with a 2x2 exit with a 2x2 QuikLock™ Coupler FBC2X2BL. Also attaches directly to 4x4 or 6x4 vertical tee exits with low profile reducer FRLPR42BL.

An image of Kit, 2
FRHD2KTOR

Provides secure, accessible route for cables spilling out from a vertical tee or spill-over junction to rack mounted equipment. Kit includes 6' length of 2x2 FiberRunner® Hinged Channel H2X2OR6, 6' length of 2x2 snap-on hinged cover HC2OR6, four adjustable "Z" brackets FZBA1.5X4, one FiberRunner® 2x2 End Cap FHDEC2X2OR, six hinged duct 2" wire retainers WR2H-C and all required mounting hardware. Attaches to 2x2 vertical tee exit or spill-over junction with a 2x2 exit with a 2x2 QuikLock™ Coupler FBC2X2OR. Also attaches directly to 4x4 or 6x4 vertical tee exits with low profile reducer FRLPR42BL.

An image of Kit, 2
FRHD2KTYL

Provides secure, accessible route for cables spilling out from a vertical tee or spill-over junction to rack mounted equipment. Kit includes 6' length of 2x2 FiberRunner®Hinged Channel H2X2YL6, 6' length of 2x2 snap-on hinged cover HC2YL6, four adjustable "Z" brackets FZBA1.5X4, one FiberRunner®2x2 End Cap FHDEC2X2YL, six hinged duct 2" wire retainers WR2H-C, and all required mounting hardware. Attaches to 2x2 vertical tee exit or spill-over junction with a 2x2 exit with a 2x2 QuikLock™Coupler FBC2X2YL. Also attaches directly to 4x4 or 6x4 vertical tee exits with low profile reducer FRLPR42BL.

An image of Spill-Over Junction Fitting with 2x2 Exit
FRSPJ2X2BL

Assembles onto 4x4, 6x4, 12x4, or 24x4 FiberRunner® Channel, spilling over the side into a 2x2 vertical exit. Requires coupler to attach 2x2 FiberRunner® and fittings to the vertical exit. Mounts directly to existing installation with no alteration required. Mounting hardware provided for secure attachment.

An image of Spill-Over Junction Fitting with 2x2 Exit
FRSPJ2X2OR

Spill-Over Junction with 2x2 Exit. Assembles onto 4x4, 6x4, 12x4, or 24x4 FiberRunner® Channel, spilling over the side into a 2x2 vertical exit. Requires coupler to attach 2x2 FiberRunner® and fittings to the vertical exit. Mounts directly to existing installation with no alteration required. Mounting hardware provided for secure attachment.

An image of Spill-Over Junction Fitting with 2x2 Exit
FRSPJ2X2YL

Assembles onto 4x4, 6x4, 12x4, or 24x4 FiberRunner®Channel, spilling over the side into a 2x2 vertical exit. Requires coupler to attach 2x2 FiberRunner®and fittings to the vertical exit. Mounts directly to existing installation with no alteration required. Mounting hardware provided for secure attachment.

An image of Accessory, Universal Innerduct Bracket, FiberRunner
FRUIB-X

Used to secure any size corrugated tubing or inner-duct to any surface including equipment racks and channel or fittings. Two 1/4" (6.3mm) holes must be drilled through to secure brackets.