infrastructure for a connected world

20
Results Found
Results per page:
An image of Copper Cable, Industrial, Cat5e, 4-pair, 26/7 AWG stranded, F/UTP, CM, Black, 1000FT/305m reel
IFC5C04BBL-CEG

Category 5e, industrial (CM), 4-pair, F/UTP copper cable; stranded copper conductors are 26/7 AWG with HDPE insulation. Conductors are twisted in pairs, surrounded by an overall metallic foil and a PVC jacket.

An image of Copper Cable, Industrial, Cat6, 4-pair, 26/7 AWG stranded, F/UTP, CM, Black, 1000ft/305m reel
IFC6C04BBL-CEG

Category 6, industrial (CM), 4-Pair, F/UTP copper cable. Conductors are 26/7 AWG construction with HDPE insulation. Conductors are twisted in pairs, surrounded by a metallic foil shield and protected by a flame-retardant PVC jacket.

An image of Copper Cable, Industrial, Cat5e, 2-pair, 24/7 AWG stranded, SF/UTP, CM, Black, 1000ft/305m reel
ISFCH5C02ABL-XG

Category 5e, industrial (CM/CMX), 2-pair, SF/UTP copper cable; stranded copper conductors are 24/7 AWG with HDPE insulation. Conductors are twisted in pairs and wrapped with a foam polypropylene tape to form a core. Both pairs are surrounded by an overall braided shield and metallic foil and covered with a TPE jacket for high flex industrial Ethernet applications. The jacket is oil, sunlight, weld splatter, and abrasion resistant for enhanced chemical resistance and mechanical performance. This cable is rated for 600 V panel or on-machine applications when the space is shared with high voltage power cables.

An image of Copper Cable, Industrial, Cat5e, 2-pair, 24/7 AWG stranded, SF/UTP, CM, Blue, 1000ft/305m reel
ISFCH5C02ABU-XG

Category 5e, industrial (CM/CMX), 2-pair, SF/UTP copper cable; stranded copper conductors are 24/7 AWG with HDPE insulation. Conductors are twisted in pairs and wrapped with a foam polypropylene tape to form a core. Both pairs are surrounded by an overall braided shield and metallic foil and covered with a TPE jacket for high flex industrial Ethernet applications. The jacket is oil, sunlight, weld splatter, and abrasion resistant for enhanced chemical resistance and mechanical performance. This cable is rated for 600 V panel or on-machine applications when the space is shared with high voltage power cables.

An image of Copper Cable, Industrial, Cat5e, 2-pair, 24/7 AWG stranded, SF/UTP, CM, Gray, 1000ft/305m reel
ISFCH5C02AGY-XG

Category 5e, industrial (CM/CMX), 2-pair, SF/UTP copper cable; stranded copper conductors are 24/7 AWG with HDPE insulation. Conductors are twisted in pairs and wrapped with a foam polypropylene tape to form a core. Both pairs are surrounded by an overall braided shield and metallic foil and covered with a TPE jacket for high flex industrial Ethernet applications. The jacket is oil, sunlight, weld splatter, and abrasion resistant for enhanced chemical resistance and mechanical performance. This cable is rated for 600 V panel or on-machine applications when the space is shared with high voltage power cables.

An image of Copper Cable, Industrial, Cat5e, 2-pair, 24/7 AWG stranded, SF/UTP, CM, Red, 1000ft/305m reel
ISFCH5C02ARD-XG

Category 5e, industrial (CM/CMX), 2-pair, SF/UTP copper cable; stranded copper conductors are 24/7 AWG with HDPE insulation. Conductors are twisted in pairs and wrapped with a foam polypropylene tape to form a core. Both pairs are surrounded by an overall braided shield and metallic foil and covered with a TPE jacket for high flex industrial Ethernet applications. The jacket is oil, sunlight, weld splatter, and abrasion resistant for enhanced chemical resistance and mechanical performance. This cable is rated for 600 V panel or on-machine applications when the space is shared with high voltage power cables.

An image of Copper Cable, Industrial, Cat5e, 2-pair, 24/7 AWG stranded, SF/UTP, CM, Teal, 1000ft/305m reel
ISFCH5C02ATL-XG

Category 5e, industrial (CM/CMX), 2-pair, SF/UTP copper cable; stranded copper conductors are 24/7 AWG with HDPE insulation. Conductors are twisted in pairs and wrapped with a foam polypropylene tape to form a core. Both pairs are surrounded by an overall braided shield and metallic foil and covered with a TPE jacket for high flex industrial Ethernet applications. The jacket is oil, sunlight, weld splatter, and abrasion resistant for enhanced chemical resistance and mechanical performance. This cable is rated for 600 V panel or on-machine applications when the space is shared with high voltage power cables.

An image of Copper Cable, Industrial, Cat5e, 2-pair, 24/7 AWG stranded, SF/UTP, CM, Yellow, 1000ft/305m reel
ISFCH5C02AYL-XG

Category 5e, industrial (CM/CMX), 2-pair, SF/UTP copper cable; stranded copper conductors are 24/7 AWG with HDPE insulation. Conductors are twisted in pairs and wrapped with a foam polypropylene tape to form a core. Both pairs are surrounded by an overall braided shield and metallic foil and covered with a TPE jacket for high flex industrial Ethernet applications. The jacket is oil, sunlight, weld splatter, and abrasion resistant for enhanced chemical resistance and mechanical performance. This cable is rated for 600 V panel or on-machine applications when the space is shared with high voltage power cables.

An image of Copper Cable, Industrial, Cat5e, 4-pair, 24/7 AWG stranded, SF/UTP, CM, Black, 1000ft/305m reel
ISFCH5C04ABL-XG

Category 5e, industrial (CM/CMX), 4-pair, SF/UTP copper cable; stranded copper conductors are 24/7 AWG with HDPE insulation. Conductors are twisted in pairs and wrapped with a foam polypropylene tape to form a core. Both pairs are surrounded by an overall braided shield and metallic foil and covered with a TPE jacket for high flex industrial Ethernet applications. The jacket is oil, sunlight, weld splatter, and abrasion resistant for enhanced chemical resistance and mechanical performance. This cable is rated for 600 V panel or on-machine applications when the space is shared with high voltage power cables.

An image of Copper Cable, Industrial, Cat5e, 4-pair, 24/7 AWG stranded, SF/UTP, CM, Blue, 1000ft/305m reel
ISFCH5C04ABU-XG

Category 5e, industrial (CM/CMX), 4-pair, SF/UTP copper cable; stranded copper conductors are 24/7 AWG with HDPE insulation. Conductors are twisted in pairs and wrapped with a foam polypropylene tape to form a core. Both pairs are surrounded by an overall braided shield and metallic foil and covered with a TPE jacket for high flex industrial Ethernet applications. The jacket is oil, sunlight, weld splatter, and abrasion resistant for enhanced chemical resistance and mechanical performance. This cable is rated for 600 V panel or on-machine applications when the space is shared with high voltage power cables.



20
Results Found
Results per page: